Issue

11.01.C

nano series Servers - Version 11.01 – Operating Manual

EVS Broadcast Equipment SA – November 2012

90

While the Replace is being performed, the following messages are displayed on the

OSD:

“Replace in Progress”

“Clipping guardbands”

“Replace by clip xxx”

On the Remote Panel, a confirmation message pops up:


9. Press

Enter on the Remote Panel to validate the Replace:

The material between the IN and OUT points is replaced with the newly created clip.

The playlist returns to Playlist Edit mode, positioned at the end of the inserted clip.

You can also cancel the Replace by pressing the

Menu key on the Remote Panel.

9.15.6 Loop Mode in the Replace Function

Loop Type

When the IN point has been marked, the display switches to:

Cam A

+2fields

Replace Int.Loop Ext.Loop

The Int. Loop and Ext. Loop keys are blinking.
Before entering the Replace Playback mode, the operator has to choose between Internal

Loop or External Loop.
The Internal Loop is the same loop as the existing loop process.
The External Loop allows you to select on which channel you will physically re-record the

output of your PGM. The link is physical: it is necessary to make the video link manually

with a router or video/audio cables; it is not done inside the server.

Additional Loop Parameters

Additional parameters are available for the external loop:

With the

Cam A function (SHIFT+C), you can select the camera the PGM will be

recorded to for the external LOOP process. Press SHIFT+C until the desired camera

is selected.

With the

+2 fields function (SHIFT+D), you can select by how much the video coming

back to your record channel will be delayed. If you are using a DVE, it could introduce

a delay. This system is based on the assumption that audio and video are in sync

when they hit the record channel. The delay value cannot be negative.
Select SHIFT+D to highlight the delay value; the display allows you to add frames or

fields of delay to the delay value. Pressing either

MENU or SHIFT+D will leave this

mode.

Replace in/out by clip xxx ?