Technical data

3 Technical data

3.1 Data

Power supply

Supply voltage

is sensor supply is made from the signal condi-

tioning instrument VEGAMET, the processing
system VEGALOG or the processing system
VEGASCAN 850 (1 … 15 sensors on one two-
wire cable)

Min. sensor voltage

17 V

Power consumption

max. 1.5 W

Current consumption

90 mA

Load (signal and supply cable)

depending on the connected sensor power
per connection cable, see following load
diagrams, however max. 15

W per wire or

max. 1000 m cable length

Supply from processing system

Supply from signal conditioning instrument

VEGASCAN 850

VEGAMET or processing system VEGALOG

Measuring range
(reference plan for sensor version B … D is the transducer end. For sensor version A, the
lower flange edge is the reference plane)

VEGASON 54

1.0 … 25 m

VEGASON 55

0.8 … 45 m

VEGASON 56

- version A

1.8 … 70 m

- version B … D

1.4 … 70 m

0

5

10

15

20

25W max.

0

100

200

300

400

500

600

700

800

900

1000m

2,5 mm

2

1,5 mm

2

0,75 mm

2

1,0 mm

2

Length of the connection cable

2,5 mm

2

1,5 mm

2

0

5

10

15

20

25W max.

0

100

200

300

400

500

600

700

800

900

1000m

0,75 mm

2

1,0 mm

2

Length of the connection cable

Total power of all sensors on one

two-wire cable

Total power of all sensors on one

two-wire cable