Data of the ib-IIC-circuit:
L

ext

max. = 1 mH

C

ext

max. = 580 nF

Data of the components:

Component

Ultrasonic

1 overvoltage

Line

Data

sensor

arrester

L

int

65

µ

H

0,13 mH

searched

C

int

~0

1 nF

searched

Determination of the line data:
L

int

= 1 mH – 0,065 mH – 0,13 mH = 0,805 mH

C

int

= 580 nF – 0 nF – 1nF = 579 nF

Calculation of the line length:

0,805 mH

l = ––––––––––– • m = 1,238 m

0,65

µ

H*

579 nF

l = –––––––––– • m = 4,825 m

120 pF*

Considering the max. VBUS-line length, the
line length in this example must not exceed
the value of 1000␣ m.

* typical values for unscreened two-wire lines: L‘ =

0,65

µ

H/m; C‘ = 120 pF/m