VEGA VEGASON 71 - 2 … 75 - 2 User Manual

Page 7

Advertising
background image

Current outputs

module

-

with

2 outputs

-

range

0/4 … 20 mA

-

resolution

0,05 % of range

-

load

max. 500 Ohm

-

load dependent
failure

at 0 … 500 Ohm, < 0,2 % related to the range

or
module

-

as above

however with 2 floating outputs each

Fail safe function

1 relay for both channels

1 spdt

contact data

as described under relay outputs

2 fail safe-LEDs

separately per channel

Ambient

ambient temperature on

conditions

-

transducer 71 … 75

–20

°

C … +80

°

C / -4 … 176

°

F

-

transducer 71 R … 73 R

–20

°

C … +55

°

C / -4 … 131

°

F

-

central electronics

–20

°

C … +60

°

C / -4 … 140

°

F

storage and transport temperature –20

°

C … +80

°

C / -4 … 176

°

F

Environmental

protection

protection

-

transducer 71 … 75

IP 68

-

transducer 71 R … 73 R

IP 68

-

housing of central electronics

IP 65

protection class

II

Electrical

terminals

for max. 1 x 1,5 mm

2

connection

cable entry

2 x Pg 7
1 x Pg 13,5, max. 5 x Pg 13,5

Material

transducer

PVDF

housing of central electronics

Polycarbonate

Weight

VEGASON

71 … 73

74 and 75

1 transducer (without cable)

approx. 0,8 kg

approx. 1,5 kg

central electronics

approx. 1,9 kg

approx. 1,9 kg

Dimensions

see dimensional drawing on following page

Technical Information

71 - 2 … 75 - 2

7

Technical data

(continuation)

Advertising