9
Measuring range
The measuring ranges described below are max.
values and can change dependent on process
conditions.
The location of the sensors should be carefully
selected and it should be noted that no struts,
edges or material inflow impede the measurement
(see installation recommendations page 10
and 11).
for liquids
VEGASON 71 - 2
72 - 2
73 - 2
74 - 2
75 - 2
Reference pane
Min.
distance
0,3 m
0,5 m
0,8 m
0,8 m
1,0 m
Measuring
range
5 m
5 m
10 m
20 m
30 m
for solids
VEGASON 73 - 2
74 - 2
75 - 2
Reference pane
Min.
distance
particle size
≥
5 mm
0,8 m
0,8 m
1,0 m
particle size
≤
5 mm 1,0 m
1,1 m
1,2 m
Measuring
range
10 m
20 m
30 m