5 at+oppanid or at+oi, 6 at+opepid or at+oe, 7 at+version or at+vr – SENA ProBee-ZS10 User Manual

Page 45: 8 at+productname or at+pn, 4 network specific parameters, 1 at+chmask or at+cm, At+oppanid or at+oi, At+opepid or at+oe, At+version or at+vr, At+productname or at+pn

Advertising
background image

45

ProBee-ZS10 User Guide Rev.1.5

5.3.5 AT+OPPANID

or

AT+OI

Description

Get the operating 16-bit PAN ID. If PAN ID is set specific value not 0s, operating PAN
ID will equal designated PAN ID. A value of “FFFF” means the device is not joined a
network.

Execute AT+OPPANID?<CR>

Response

<value><CR>
OK<CR>

5.3.6 AT+OPEPID

or

AT+OE

Description

Get the operating 64-bit extended PAN ID. A value of “FFFFFFFFFFFFFFFF” means
the device is not joined a network.

Execute AT+OPEPID?<CR>

Response

<value><CR>
OK<CR>

5.3.7 AT+VERSION

or

AT+VR

Description

Get firmware version of the module. The firmware version returns a form of “PTvx.x”.

Execute AT+VERSION?<CR>

Response

<value><CR>
OK<CR>

5.3.8 AT+PRODUCTNAME

or

AT+PN

Description

Get the product name. It can be used to distinguish among different hardware
platforms.

Execute AT+PRODUCTNAME?<CR>

Response

<value><CR>
OK<CR>

5.4

Network Specific Parameters

5.4.1 AT+CHMASK

or

AT+CM

Description

Get/Set the channel mask to use. Bits set as 1 indicate that this particular channel can
be used. Bits set as 0 indicate that this particular channel should not be used. For
example, a channel mask value of 0x00000001 indicates that only channel 0 should be
used. Valid channels range from 12 to 25 inclusive. (14 channels are available.) This
translates to a channel mask value of “0x03FFF000”.

Execute AT+CHMASK?<CR>

AT+CHMASK=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR> or ERROR<CR>

Default 03FFF000