47

ProBee-ZS10 User Guide Rev.1.5

5.4.6 AT+STACK

or

AT+ZS

Description

Get/Set the ZigBee stack profile value. This value must be set the same on all devices
that should join the same network. (0: Network specific, 1: ZigBee, 2: ZigBee Pro)

Execute AT+STACK?<CR>

AT+STACK=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR> or ERROR<CR>

Default 0
Range

0 - 2

5.4.7 AT+NODENAME

or

AT+NN

Description

Get/Set the node name. It can be used to make a clear distinction role or functionality
of local node from others.

Execute AT+NODENAME?<CR>

AT+NODENAME=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR> or ERROR<CR>

Default ProBee-ZS
Range

Up to 16 characters

5.5

Network Formation and Join

5.5.1 AT+ASCAN

or

AT+AS

Description

Perform a scanning for existing network. It can take up to 5 seconds.
(CAUTION: It is possible to cause a link error if a node is a parent of an end-device.)

Execute AT+ASCAN<CR>

AT+ASCAN=<channel mask><CR>

Response

<channel>|<PAN ID>|<EPID>|<joinable>|<stack profile>

List of the existing networks

OK<CR>

5.5.2 AT+ESCAN

or

AT+ES

Description

Perform a scanning for energy level of all channels. It can be used to avoid
interference. It can take up to 5 seconds. The RSSI energy level ranges from
approximately -100 to +127 in dBm at PTv1.4 or later. It is the real RSSI value plus an
offset of +154 at PTv1.3 or earlier. (CAUTION: It is possible to cause a link error if a

node is a parent of an end-device.

)

Execute AT+ESCAN<CR>

AT+ESCAN=<channel mask><CR>

Response

<channel>|<RSSI >

List of the RSSI for each channel

OK<CR>