7 data transmission and reception, 1 at+destla or at+dl, 2 at+destgroupid or at+dg – SENA ProBee-ZS10 User Manual

Page 50: 3 at+sinkinfo or at+si, 4 at+maxpayload or at+mp, 5 at+trasnsmitmode or at+tm, Data transmission and reception, At+destla or at+dl, At+destgroupid or at+dg, At+sinkinfo or at+si

Advertising
background image

50

ProBee-ZS10 User Guide Rev.1.5

5.7

Data Transmission and Reception

5.7.1 AT+DESTLA

or

AT+DL

Description

Get/Set the 64-bit destination IEEE address for unicast data transmission.

Execute AT+DESTLA?<CR>

AT+DESTLA=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR> or ERROR<CR>

Default 0000000000000000
Range

0000000000000000 - FFFFFFFFFFFFFFFF

5.7.2 AT+DESTGROUPID

or

AT+DG

Description

Get/Set the 16-bit destination Group ID for multicast data transmission.

Execute AT+DESTGROUPID?<CR>

AT+ DESTGROUPID=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR> or ERROR<CR>

Default 0000
Range

0000 – FFFF

5.7.3 AT+SINKINFO

or

AT+SI

Description

Get the long and short addresses of sink node. If there is no sink node in the network,
the addresses will be “FFFFFFFFFFFFFFFF” and “FFFF”.

Execute AT+SINKINFO?<CR>

Response

<IEEE address>,<nodeID><CR>
OK<CR>

5.7.4 AT+MAXPAYLOAD

or

AT+MP

Description

Get the maximum size of the payload that the Application Support sub-layer will
accept. The size depends on the security level in use.

Execute AT+MAXPAYLOAD?<CR>

Response

<value><CR>
OK<CR>

5.7.5 AT+TRASNSMITMODE

or

AT+TM

Description

Get/Set the data transmission mode. This mode is maintained after rebooting. (0:
none, 1: unicast to destination long address, 2: multicast to destination group ID, 3:
broadcast to all nodes, 4: unicast to sink node)

Execute AT+TRANSMITMODE?<CR>

AT+TRANSMITMODE=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR> or ERROR<CR>

Default 0