5 s55, 6 s56, 5 sink – SENA ProBee-ZS10 User Manual

Page 66: 1 s61, 2 s62, Sink

Advertising
background image

66

ProBee-ZS10 User Guide Rev.1.5

Range

0 – 10000

7.4.5 S55

Description

Get/Set the rejoin timeout. If it is enabled, an end-device tries to rejoin the current
network when contact with the network has been lost for setting value in seconds. The
most common usage case is when an end-device can no longer communicate with its
parent and wishes to find a new one.

Execute ATS55?<CR>

ATS55=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR>

Default 10
Range

0 – 10000

7.4.6 S56

Description

Get/Set the end-device poll period in seconds. Adaptive polling may allow the end-
device to poll more rapidly for a short time when receiving RF data.

Execute ATS56?<CR>

ATS56=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR>

Default 5
Range

0 – 10000

7.5 Sink

7.5.1 S61

Description

Get/Set the sink node and the sink advertise period in seconds. When a node is
defined as a sink, it can multicast its address to the rest of the network in this period.
If set to 0, sink advertise is disabled.

Execute ATS61?<CR>

ATS61=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR>

Default 0
Range

0 – 10000

7.5.2 S62

Description

Get/Set the period to send Many-to-One Route Request. Many-to-One Route Request
(MTOR) creates routes from every node in the network back to this node. It is useful
when this node acts as a sink node.

Execute ATS62?<CR>

ATS62=<value><CR>

Response <value><CR>

OK<CR>

Advertising