3 at+parity or at+up, 4 at+stopbit or at+us, 5 at+flowctrl or at+uf – SENA ProBee-ZS10 User Manual

Page 53: 10 firmware upload and help, 1 at+bootload or at+bl, At+parity or at+up, At+stopbit or at+us, At+flowctrl or at+uf

Advertising
background image

53

ProBee-ZS10 User Guide Rev.1.5

5.9.3 AT+PARITY

or

AT+UP

Description

Get/Set the serial parity setting on the module.

Execute AT+PARITY?<CR>

AT+PARITY=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR> or ERROR<CR>

Default 0
Range

0 - 2

5.9.4 AT+STOPBIT

or

AT+US

Description

Get/Set the serial stop bit setting on the module.

Execute AT+STOPBIT?<CR>

AT+STOPBIT=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR> or ERROR<CR>

Default 1
Range

1 - 2

5.9.5 AT+FLOWCTRL

or

AT+UF

Description

Get/Set flow control status. (0: none, 1: software, 2: hardware flow control)

Execute AT+FLOWCTRL?<CR>

AT+FLOWCTRL=<value><CR>

Response

<value><CR>
OK<CR>

OK<CR> or ERROR<CR>

Default 0
Range

0 - 2

5.10 Firmware Upload and Help

5.10.1 AT+BOOTLOAD

or

AT+BL

Description

Start bootloader to upload firmware. (blank: local, 1: passthru, 2: clone)
The device leaves the AT command line and enters the bootloader menu for uploading
new ProBee firmware. There’s no restrict to use local upload but a sleepy end-device
cannot upload to remote node over the air. The current UART should be set
115200bps, 8 data bits, no parity, 1 stop bit and none flow control.

Execute AT+BOOTLOAD<CR>

AT+BOOTLOAD=<number>,<IEEE><CR>

Response

Bootloader menu


Serial upload complete

Please start .ebl upload image ...<CR> or
Start cloning ...<CR>

Bootloader menu


Bootload Complete!

Advertising