stored into the non-volatile memory space of the Pro Series, but the settings will not be stored until

users enter ”save” command on the menu. All the configuration change will be effective after entering

“apply” command on the menu.

2.2.6. Using Remote console

The IP address of the Pro Series must be known before users can access the Pro Series using the

Remote console (see chapter 3. Network Configuration for details). The default IP address of Pro

Series is 192.168.161.5.

The Remote console access function can be disabled in the remote host access option (3.6 IP

Filtering for details).

The following instructions will assist in setting up the Remote Console functionality:

1)

]Run either a Telnet program or a program that supports Telnet functions (i.e. TeraTerm-Pro

or HyperTerminal). The target IP address and the port number must match the Pro Series. If

required, specify the port number as 23. Type the following command in the command line

interface of user’s computer.

telnet 192.168.161.5

Or run a Telnet program with the following parameters:

Figure 2-8 Telnet program set up example (TeraTerm Pro)

2)

The user must log into the Pro Series. Type the user name and password. A factory default

settings of the user name and password for CLI login are both root.

3)

After entering correct user name and password, user can see the CLI prompts .