SENA PS210W User Manual

Page 49

Advertising
background image

49

Figure 4-6 Host mode configuration (UDP mode)

1) Operations

If a remote host sends a UDP datagram to the one of UDP Local port of the Pro Series, Pro Series first

checks whether it is from one of the hosts configured on remote host configuration.

If the remote host

is one of the hosts configured on remote host configuration, then Pro Series transfers the data through

the serial port. Otherwise, the Pro Series discards the incoming UDP datagram. But user can force Pro

Series accept all incoming UDP datagram regardless remote host configuration by setting Accept UDP

datagram from unlisted remote host parameter as ‘Yes’. If there is any incoming data from the serial

port, the Pro Series transfers the data to the remote host defined on remote host configuration. If the

remote port is not opened, the Pro Series will not transfer the data.

2) Parameters

UDP receiving port

The concept is the same as TCP listening port. See TCP mode parameters in the section 4.2.3.1.

for details.

Max. allowed connection

The concept is the same as that of TCP communication. See TCP mode parameters in the

section 4.2.3.1. for details.

Accept UDP datagram from unlisted remote host

If Accept unlisted (Accept UDP datagram from unlisted remote host) function is set as ‘No’, Pro

Series will accept only incoming UDP datagram from the remote host(s) configured on remote

Advertising