SCANTECH ID (Champtek company) Discovery SG-20 User Manual

Page 66

Advertising
background image

Ethernet Configuration

58

6.3.3

Checking the internal Discovery communication

settings

Select

a

1

a

in order to check the communication settings between the

Discovery unit itself and the Ethernet module. NOTE: The Discovery/Ethernet is

supplied from the factory with the following settings:

At Discoveries with hardware P/N A360103: Jumpers in RS-232 mode,

data-comm settings: 9600 Baud, 8 data, 1 stop bit, echo off, RTS/CTS

off. CR (! SG-20 Default).

Since Discoveries with hardware P/N A360104 or higher, the data-comm

speed is increased with a factor 4 to: 38.400 baud, 8 data, No parity, 1,

Echo Off, RTS/CTS On.

The communication settings of the Discovery unit itself can be checked

(and corrected if necessary) by entering the Service Menu, using the 4

buttons. See Chapter 5 for details.

3.1

Baudrate (9600)

38400

a a

a a

keep (9600) at

Discovery with P/N

A360103

3.2

I/F Mode (4C) ?

a

a

3.3

Flow (00) ?

02

a

a

a a

keep (00) at

Discovery with P/N

A360103

3.4

Port No (01024) ?

a

a

3.5

Connect Mode

(00)

C5

5

a

= Autoconnect mode (= client

mode), i.e. after power-up the unit looks

automatically for contact

Advertising