SCANTECH ID (Champtek company) Discovery SG-20 User Manual

Page 49

Advertising
background image

Scantech-ID Discovery SG-20

41

- Ethernet (optional, see page 60).

ATTENTION

1. As of partnumber A360104) the interface can be selected by

using this menu. Previous versions use jumpers on the main

board (Chapter 4.1”Interfaces”).

2. The Ethernet interface is optional and is only available if an

Ethernet module is placed inside the Discovery.

3. All interfaces use the same port on the back of the Discovery. If

switched from Ethernet to another interface, the Discovery

should be opened to bypass the Ethernet module.

Screen 3.1.2

Select next field

Increase value of current field

Decrease value of current field

Back to screen 3.1

RS485 Settings :

Address

: The RS485 address (1 - 32)

Protocol

: - Standard

: The standard RS485 protocol

- Enhanced : A slightly enhanced protocol, decreasing

network traffic.

Terminator

: Enables or Disables the termination resistor. Should only

be used on the last physical Discovery in the network.