Opceip ethernet/ip – GE Industrial Solutions AF-600 FP OPCEIP EtherNet_IP User Manual

Page 51

Advertising
background image

Warnings
All warnings within the frequency converter are represented by a single bit within a warning word. A warning word is always an action parameter. Bit status FALSE
[0] means no warning, while bit status TRUE [1] means warning. Each bit status has a corresponding text string message. In addition to the warning word message
the master will also be notified via a change in the status word.

Alarms
Following an alarm message the frequency converter will enter a fault condition. Only after the fault has been rectified and the master has acknowledged the
alarm message by a bit in the Control Word, can the drive resume operation. All alarms within the drive are represented by a single bit within an alarm word. An
alarm word is always an action parameter. Bit status FALSE [0] means no alarm, while bit status TRUE [1] means alarm. In CIP, Alarms are divided in to two
categories:

-

Major Recoverable Faults

-

Major Unrecoverable Faults

Please refer to the following sections for a classification of the specific faults.

Bit (Hex)

Alarm word (Par. DR-90)

CIP Classification

00000001

Brake check

-

00000002

Power card over temperature

MAR

00000004

Earth fault

MAU

00000008

Ctrl. card over temperature

-

00000010

Control word timeout

MAR

00000020

Torque limit

MAU

00000040

Over current

MAR

00000080

Motor thermistor over temp.

MAR

00000100

Motor Electronic Thermal Overload over temperature

MAR

00000200

Inverter overloaded

MAR

00000400

DC link under voltage

MAR

00000800

DC link over voltage

MAR

00001000

Short circuit

MAU

00002000

Inrush fault

MAR

00004000

Mains phase loss

MAU

00008000

Auto Tune not OK

MAR

00010000

Live zero error

MAR

00020000

Internal fault

MAU

00040000

Brake overload

MAU

00080000

Motor phase U is missing

MAU

00100000

Motor phase V is missing

MAU

00200000

Motor phase W is missing

MAU

00400000

Network fault

MAR

00800000

24V supply fault

MAU

01000000

Mains failure

MAR

02000000

1.8V supply fault

MAU

04000000

Brake resistor short circuit

MAR

08000000

Brake chopper fault

MAR

10000000

Option change

-

20000000

Drive initialized

-

40000000

Safe Stop

MAR

80000000

Mech. Brake low

-

MAR = Major Recoverable Fault
MAU = Major Unrecoverable Fault

OPCEIP EtherNet/IP

50

7

Advertising