Object ID

Object Name

Read/Write

Changeable

Description

Non volatile ram

Store

AF-600 FP Pa-

rameter

Alarm
notifi-

cation

Triggers Bus Time-

out

AV:31

Ext. 2 Setpoint

W/R

No

AF-600 FP

XC-35

No

No

AV:32

Ext. 2 reference [Unit]

W/R

No

AF-600 FP

XC-37

No

No

AV:33

Ext. 2 Feedback [Unit]

W/R

No

AF-600 FP

XC-38

No

No

AV:34

Ext. 2 Proportional Gain

W/R

No

AF-600 FP

XC-41

No

No

AV:35

Ext. 2 Integral Time (Sec)

W/R

No

AF-600 FP

XC-42

No

No

AV:36

Ext. 2 Differential Time

W/R

No

AF-600 FP

XC-43

No

No

AV:37

Ext. 2 Dif. Gain

W/R

No

AF-600 FP

XC-44

No

No

AV:38

Ext. 3 Setpoint

W/R

No

AF-600 FP

XC-55

No

No

AV:39

Ext. 3 Reference [Unit]

W/R

No

AF-600 FP

XC-57

No

No

AV:40

Ext. 3 Feedback [Unit]

W/R

No

AF-600 FP

XC-58

No

No

AV:41

Ext. 3 Proportional Gain

W/R

No

AF-600 FP

XC-61

No

No

AV:42

Ext. 3 Integral Time (Sec)

W/R

No

AF-600 FP

XC-62

No

No

AV:43

Ext. 3 Differential Time

(Sec)

W/R

No

AF-600 FP

XC-63

No

No

AV:44

Ext. 3 Dif. Gain Limit

W/R

No

AF-600 FP

XC-64

No

No

Table 5.1: Analog values cont.

5.2.2 Binary Input- and Output Objects

Object Id

Object Name

Read/Write

Changeable De-
scription

Non volatile
ram Store

Drive Par.

Alarm
notifi-
cation

Triggers Bus
Timeout

BI:0

Digital input 33

Read

No

No

DR-60/00

No

No

BI:1

Digital input 32

Read

No

No

DR-60/01

No

No

BI:2

Digital input 29

Read

No

No

DR-60/02

No

No

BI:3

Digital input 27

Read

No

No

DR-60/03

No

No

BI:4

Digital input 19

Read

No

No

DR-60/04

No

No

BI:5

Digital input 18

Read

No

No

DR-60/05

No

No

BI:6

Digital input 37

Read

No

No

DR-60/06

No

No

BI:7

Digital input X30/2

Read

No

No

DR-60/07

No

No

BI:8

Digital input X30/3

Read

No

No

DR-60/08

No

No

BI:9

Digital input X30/4

Read

No

No

DR-60/09

No

No

BI:10

Digital input DR-60/10*

Read

No

No

DR-60/10

No

No

BI:11

Digital input DR-60/11*

Read

No

No

DR-60/11

No

No

BI:12

Digital input DR-60/12*

Read

No

No

DR-60/12

No

No

BI:13

Digital input DR-60/13*

Read

No

No

DR-60/13

No

No

BI:14

Digital input DR-60/14*

Read

No

No

DR-60/14

No

No

BI:15

Digital input DR-60/15*

Read

No

No

DR-60/15

No

No

Table 5.1: Binary inputs
Bl:7 - Bl:19 values are only available if the option is installed.
*) Reserved for future options!

AF-600FP BACnet