GEI-100343

5.6. CFIX:HXED WORD COMMUNICATION

SYMBOL:

0

2

3

_

4

_

5

6

_

7

CFIX

FUNCTION:

It defines a communication of 0, 1, 2 or 3 Fixed Words to be transmitted and/or received at every Bricks execu-
tion in RUN status. When this block is used, it defines the card as a client for this communication. The commu-
nication is enabled with the appropriate bit of the “SlaveMapLow” or “SlaveMapHigh” parameters. The Bricks
programmer will supply an instance of this Brick with the Slave ID, the number of words to be transmitted to

and/or received from the slave, the source and/or destination in FWA and the IVARS of the master to be trans-

mitted and/or received.

BLOCK INPUT

md

name

type

description

0

Slave_id

mt

0 ... 63; slave identifier

1

Lenw

mt

0 ... 3; number of words transmitted

2

Fix_Dst md

mt

0 ... 47 Fixed Word index of the destination

3

md Ivar Src

mt

0... 199. IVAR index of the source

4

Len_r

mt

o ... 3; number of words required

5

Fix_Src md

mt

0 ... 47 Fixed Word index of the source

6

md_Ivar_dst

mt

0... 199. IVAR index of the destination

7

Tmo

mt

time-out [number

of Bricks executioni

TNet4O

BLOCK OUTPUT

md

name

type

description

Q

mt

result: 0 = connection executed with no errors

1 = connection in execution

2 = time-out elapsed

TNet5O

MAXIMUM NUMBER OF BLOCKS: 32

if you use WIN+DRIVE, the CFIX functions are the same but change inputs and output (see

the DGFC manual)

HI”’

HOW TO EXCHANGE 110 DATA

Sieve_id
Len_w
Fix_dst_md
md var_scr
Len_r
Fix_scr_md
md var_dst
Tmo

NOTE: