L)evlceiNet

5.7. RFlX: READ FIXED WORD

SYMBOL:

0

2

3

RFIX

FUNCTION:

This block is used on

the server device to read one (or two) words of FWA and to write the value in a defined

xVAR. Note that the client is able to write only

in the FWA of the server. The type of var where the value is to be

copied is an input. It is possible to select integer type for IVAR or float type for VAR (in this case 2 words will

be read) .Note that this Brick acts internally to the slave DGFC, and no DeviceNet communication is involved.

md

name

type

description

D

Ind_fix

mt

0 ... 47; index of FWA, it is the Fixed Word (s) to

be read

1

Ind_var

mt

0... 199; Index of the xVAR wherethe value read
in FWA is written.

2

Type var

mt

Type of the xVAR read. The used values are:

3 = integer (IVAR)
7

float (VAR)

3

Tmo

mt

time-out [number

of execution Bricksj

TNet6O

BLOCK OUTPUT

md

name

type

description

mt

fresult: 0

new fixed value available

1= already read value on fixed area

2= time-out elapsed

Q

MAXIMUM NUMBER OF BLOCKS: 32

NOTE:

if you use WIIN+DRIYE, the

RFIX

functions are the same but change inputs

and output (see

the

DGFC

manual)

LYIB

HOW TO EXCHANGE 110 DATA

TNeI7O

md_fix

Indvar

Q

Type var

Tmo

BLOCK INPUT