2 ordering – GE Industrial Solutions GERAPID 2607, 4207, 6007, 8007 with arc chutes 1X2, 1X4, 2X2, 2X3, 2X4 User Manual

Page 52

Advertising
background image

52

Design and specifications are subject to change without notice

S47183e rev.03 2010-06-07

7.2 Ordering.

Gerapid

with arc chute

APN460437 rev03 09/2009

Quantity

to

Diagram no:
Customer's reference no.

Opt

Code

Code

1

1

5

2

2

6

3

3

7

4

4

5
6

1

4

7

2

5

8

3

6

9

S

E

10

1

7

11

2

8

12

3

9

13

4

A

14

5

B

15

6

R

16

1

5

17

2

6

18

3

R

19

4

20

B

21

S

22

1

0

23

2

24

1

25

2

0

26

1

5

27

2

6

28

3

7

29

4

8

30

kA

kA

kA

kA

kA

kA

0

31

kA

kA

kA

kA

kA

kA

32

1

4

33

2

5

34

3

R

35

1

4

36

2

R

37

3

38

0

39

[KSM]: code 10

1

40

0

4

41

1

5

42

2

6

43

3

44

0

2

45

[EDA]: code 12

1

3

46

0

47

[ZWA]: code 13

1

48

0

49

[STA]: code 14

1

50

0

2

51

[SCH]: code 15

1

52

0

53

[HAN]: code 16

1

54

0

55

[LBM]: code 17

1

56

0

57

[ZAL]: code 18

1

58

1

3

59

2

4

60

[SST]: code 19

R

61

1

4

62

2

63

[CUS]: code 20

3

R

64

En

Ch

65

De

R

On Request

On Request

On Request

125 V AC

Unlock "On Request" options.

Breaker number:

Special ratings tested by customer.

2X3 (3000 V)
2X4 (3600 V)
EF4-12 (3600 V)
110 V AC
120 V AC

On request

Name

Gerapid 8007R
Gerapid 10007R
Gerapid 8007DS

Impulse coil with internal C-bank (NEKO)
-

Relevant standard

China acc. IEC947-2 & GB14048.2

Military type acc. MIL-C-5015G

English

Documentation Language

LV DC acc. IEEEC37.14

[LNG]:

Contact position indicator

ED impulse coil release

Without

With

With

With
Without

Without

Closing solenoid supply voltage

Without

5 convertible contacts

With
Without

9 convertible contacts

Forced tripping release

Without
Impulse coil w/o internal C-bank

With
Without
Sidewalls protection panels
Without

Rodent proofing

German

Catalogue no:

Arc chute type

[LIC]: code 2

1X4 (2000 V)
2X2 S (1500 V)

V/H

Fixed setting up to 15 kA

Ta = 35 °C

Top connector '-'

250 V DC

without SEL

Not apply

Heavy Industry type

LV DC acc. IEC60947-2

Standard Shunt Trip

Shunt Trip - external 220 V DC

Chinese

Mechanical Counter

Control connectors type

Railway & Industry applications

Counter

Gearapid SE retrofit

[POL]: code 5
SEL operation temperature

[TSEL]: code 6

OC release

Threshold [kA]

Auxiliary tripping releases

Shunt Trip - external 110 V DC

[STE]: code 3

Auxiliary contacts quantity

Without

[HIL]: code 11

OC trip target

[HIS]: code 9

Protection options

Lever for manual operating

Arc chute presence

Railway DC acc. EN50123-2

[KSA]: code 7

[NET]: code 8

Control circuits supply voltage

Requested marks on the scale

33 .. 85 V DC

Adjustable up to 15 kA

-

24 V/24 V (DC stabilizer)

Adjustable up to 24 kA

Fixed setting up to 24 kA

3 convertible contacts

Ta = 55 °C

external 24 V DC±5%

Polarized adj. 0,4 kA - 1,2 kA

Main terminals layout
Top/Bottom

Top connector '+'

Main terminals polarization

H/H - (H)orizontal

V/V

[ANS]: code 4

Polarized adjust. 0,8 kA - 2,5 kA

2X2 (2000 V)

Shunt Trip - external 125 V DC

88 .. 145 V DC
125 .. 353 V DC / 115 .. 240 V AC

10 convertible contacts

Gerapid 8007

60 V DC

48 V DC

220 V DC

110 V DC
125 V DC

1X2 (1000 V)
1X3 (1500 V)

Gerapid 4207

Name

Breaker type

Gerapid 2607

[BAU]: code 1

Code Name

Gerapid 6007

230 V AC
240 V AC

Special type B
Special type S

For SEL 6 kA
For SEL 12 kA
On Request

H/V - (V)ertical

On Request

Standard Zero Voltage Release

Without OCT

On Request

Polarized adjust. 2 kA - 6 kA
Polarized adjust. 4 kA - 8 kA

=>

=>

=>

Advertising