Extron Electronics TPX 88 A User Guide User Manual

Page 77

Advertising
background image

A-3

TPX 88 Matrix Switchers • Reference Information

Gain error ...................................... ±0.1 dB channel to channel
Maximum level (Hi-Z) ................ >+21 dBu, balanced or unbalanced at 1%THD+N
Maximum level (600 ohm) ......... >+15 dBm, balanced or unbalanced at 1%THD+N

Control/Remote — switcher

Serial control port ........................ RS-232 or RS-422, 5-pole captive screw connector
Baud rate and protocol ............... 9600 baud, 8 data bits, 1 stop bit, no parity
Pin configurations

RS-232 ................................... 3 = TX, 5 = RX, 1= GND
RS-422 ................................... 2 = TX-, 3 = TX+, 4 = RX-, 5 = RX+, 1= GND

Program control ........................... Extron’s control program for Windows

®

Extron’s Simple Instruction Set (SIS

)

General

Power ............................................. 100 VAC to 240 VAC, 50/60 Hz, 25 watts, internal, autoswitchable
Temperature/humidity .............. Storage -40° to +158°F (-40° to +70°C) / 10% to 90%, noncondensing

Operating +32° to +122°F (0° to +50°C) / 10% to 90%, noncondensing

Rack mount ................................... Yes, with optional brackets
Enclosure type .............................. Metal
Enclosure dimensions ................. 1.75" H x 17.5" W x 9.5" D (1U high, full rack wide)

4.4 cm H x 44.5 cm W x 24.1 cm D
(Depth excludes connectors and knobs.)

Product weight ............................. 3.5 lbs (1.6 kg)
Shipping weight ........................... 7 lbs (3.2 kg)
DIM weight .................................. 25
Vibration ....................................... ISTA 1A in carton (International Safe Transit Association)
Listings .......................................... UL, CUL
Compliances ................................. CE, FCC Class B, VCCI, AS/NZS, ICES
MTBF ............................................. 30,000 hours
Warranty ....................................... 3 years parts and labor

All nominal levels are at ±10%.

Specifications are subject to change without notice.