Controlling image capture

PIKE Technical Manual V5.1.2

223

In this case the camera can resynchronize the horizontal clock to the new trig-
ger event, leaving only a very short uncertainty time of the master clock period.

Model

Exposure start jitter
(while FVal)

Exposure start jitter
(while camera idle)

Pike F-032

 4.9 μs

 375 ns

Pike F-100

 8.2 μs

 1.65 μs

Pike F-145

 16 μs

 2.9 μs

Pike F-145-15fps

 30 μs

5.4 μs

Pike F-210

 14.25 μs

 1.8 μs

Pike F-421

15 μs

1.65 μs

Pike F-505

17 μs

5.7 μs

Pike F-1100

single tap:

141 μs

dual tap:

74.5 μs

7.64 μs
(single+dual tap)

Pike F-1600

single tap:

177 μs

dual tap:

95.7 μs

13.6 μs
(single+dual tap)

Table 78: Jitter at exposure start (no binning, no sub-sampling)

Note

Jitter at the beginning of an exposure has no effect on
the length of exposure, i.e. it is always constant.