Configuration of the camera

PIKE Technical Manual V5.1.2

316

530h

TRIGGER_INQ

Presence_Inq

[0]

Indicates presence of this
feature (read only)

Abs_Control_Inq

[1]

Capability of control with
absolute value

---

[2..3

Reserved

Readout_Inq

[4]

Capability of reading out the
value of this feature

ON_OFF

[5]

Capability of switching this
feature ON and OFF

Polarity_Inq

[6]

Capability of changing the
polarity of the trigger input

---

[7..15]

Reserved

Trigger_Mode0_Inq [16]

Presence of Trigger_Mode 0

Trigger_Mode1_Inq [17]

Presence of Trigger_Mode 1

Trigger_Mode2_Inq [18]

Presence of Trigger_Mode 2

Trigger_Mode3_Inq [19]

Presence of Trigger_Mode 3

---

[20..31

Reserved

534h

TRIGGER_DELAY_INQUIRY Presence_Inq

[0]

Indicates presence of this
feature (read only)

Abs_Control_Inq

[1]

Capability of control with
absolute value

---

[2]

Reserved

One_Push_Inq

[3]

One Push auto mode Con-
trolled automatically by the
camera once)

Readout_Inq

[4]

Capability of reading out the
value of this feature

ON_OFF

[5]

Capability of switching this
feature ON and OFF

Auto_Inq

[6]

Auto Mode (Controlled auto-
matically by the camera)

Manual_Inq

[7]

Manual Mode (Controlled by
user)

Min_Value

[8..19]

Minimum value for this fea-
ture

Max_Value

[20..31]

Maximum value for this fea-
ture

538 .. 57Ch

Reserved for other FEATURE_HI_INQ

Register

Name

Field

Bit

Description

Table 145: Feature elements inquiry register