background image

Configuration of the camera

PIKE Technical Manual V5.1.2

371

6.

Set EnableMemWR to false.

To read a DPC coordinates:

1.

Query the limits and ranges by reading DEFECT_PIXEL_CORRECTION_INFO
and GPDATA_INFO.

2.

Query NumberDefectColumn and NumberDefectPixel from
DEFECT_PIXEL_CORRECTION_MEM

3.

Set EnableMemRD to true (1).

4.

Read n DPC data bytes from GPDATA_BUFFER (n might be lower than the
size of the GPDATA_BUFFER).

5.

Repeat step 4 until all data is transferred.

6.

Set EnableMemRD to false.