ALLIED Vision Technologies Pike F-1600 User Manual

Page 49

Advertising
background image

Filter and lenses

PIKE Technical Manual V5.1.2

49

Focal length

for type 1 sensors

PIKE F-210

Distance = 0.5 m

Distance = 1 m

8 mm

0.6 m x 0.8 m

1.2 m x 1.6 m

12 mm

0.39 m x 0.52 m

0.78 m x 1.2 m

16 mm

0.29 m x 0.38 m

0.58 m x 0.76 m

25 mm

18 cm x 24 cm

36 cm x 49 cm

35 mm

13 cm x 17 cm

26 cm x 34 cm

50 mm

8.8 cm x 12 cm

18 cm x 23 cm

Table 11: Focal length vs. field of view (PIKE F-210)

Note

Lenses with focal lengths < 35 mm will very likely show exces-
sive shading in the edges of the image due to the fact that the
image size of the sensor is slightly bigger than the C-mount
itself and due to microlenses on the sensor's pixel.

Ask your dealer if you require non C-Mount lenses.

Focal length

for type 1.2 sensors

PIKE F-421

Distance = 0.5 m

Distance = 1 m

35 mm

20 cm x 20 cm

42 cm x 42 cm

50 mm

14 cm x 14 cm

29 cm x 29 cm

Table 12: Focal length vs. field of view (PIKE F-421)

Focal length

for type 35 mm sensors

PIKE F-1100/F-1600

Distance = 0.5 m

Distance = 1 m

18 mm

64 cm x 96 cm

1.3 m x 2.0 m

21 mm

55 cm x 82cm

1.1 m x 1.7 m

25 mm

46 cm x 68 cm

0.94 m x 1.4 m

28 mm

41 cm x 61 cm

0.83 m x 1.3 m

35 mm

32 cm x 48 cm

66 cm x 99 cm

50 mm

22 cm x 32 cm

46 cm x 68 cm

90 mm

11 cm x 16 cm

24 cm x 36 cm

Table 13: Focal length vs. field of view (PIKE F-1100/F-1600)

Advertising