ALLIED Vision Technologies Bonito CL-400 200 fps User Manual

Page 23

Advertising
background image

Camera interfaces

Bonito Technical Manual V2.3.0

23

The baud rate is factory-set to 115200 but can also be configured to other val-
ues: see chapter

Serial control interface configuration (s)

on page 66.

All command examples are formatted in the following styles:

Bold Courier font: characters sent to the camera

Courier font: the camera’s answer

At power-up the camera loads the stored parameter configuration from its non-
volatile memory and sends a start message after successful initialization to all
activated serial interfaces.

The following is an example of the start message

Bonito CL / CMC-4000 CMOS High-Speed Camera
Version: CMC.040.xx.yy
>

The command prompt character

> indicates that the camera is ready to receive

and process the next command. Each command consists of a command letter,
followed by an equality sign and a parameter value in hexadecimal number rep-
resentation. The command letter is case sensitive. Hexadecimal values are
always upper case and are 1 to 8 hex digits long. The command is activated by a
carriage return ([CR], ASCII character number 0D). Serial communication oper-
ates in echo mode by default. This means that each character received by the
camera is echoed back to the sender.

For that reason, all serial commands (exceptions:

V

,

Y

,

a

,

?) have the fol-

lowing general syntax:

>A=wxyz[CR]

The following example sets the exposure time to 1000 = 3E8 time units:

1.

User sends the six characters
E=3E8[CR]

2.

Camera answers with nine characters (echo followed by new prompt)
E=3E8[CR][CR][LF]>

Sign

Description

A

Command or parameter letter
(observe upper and lower case printing!)

=

Equality sign (3D)

wxyz

1-8 digits long value in hexadecimal number representation
(capital letters)

[CR]

Carriage Return (0D)

[LF]

Line Feed (0A)

Table 4: Syntax of serial commands

Advertising
This manual is related to the following products: