ALLIED Vision Technologies Bonito CL-400 200 fps User Manual

Page 67

Advertising
background image

Parameters and commands

Bonito Technical Manual V2.3.0

67

To set a sub-field to a certain value, modify the associated bit group by allocat-
ing

s to the appropriate hexadecimal number.

Since all of the sub-fields are set using the parameter

s, it is only possible to set

all of them at the same time. The value of

s is calculated as the aggregate sum

of the hexadecimal values that are set to each of the three sub-fields.

The table below shows the hexadecimal values that can be set for each sub-
field. To work out the final value for

s, select the usage for each sub-field, then

add the corresponding hexadecimal values.

F

E

D

C

B

A

9

8

7

6

5

4

3

2

1

0

-

-

-

-

-

-

-

-

e

a

a

-

x

x

x

x

-

-

-

-

-

-

-

- rw rw rw

rw rw rw rw

Table 27: Order of bit groups within parameter

s

Bit values

Settings

Weight
(hexadecimal)

Baud rate of the serial ports

xxx-0000 110 Baud *

0

xxx-0001 300 Baud *

1

xxx-0010 600 Baud *

2

xxx-0011 1,200 Baud *

3

xxx-0100 2,400 Baud *

4

xxx-0101 4,800 Baud *

5

* Baud rates up to 4,800 Baud are not available via Camera Link.

xxx-0110 9,600 Baud

6

xxx-0111 19,200 Baud

7

xxx-1000 38,400 Baud

8

xxx-1001 57,600 Baud

9

xxx-1010 115,200 Baud

A

Enable state of the serial ports

x00-xxxx RS232 via 15-pin D-sub connector only.

0

x01-xxxx Additionally activates second channel via

Camera Link connector O2.

20

x10-xxxx Additionally activates second channel via

Camera Link connector O4.

40

x11-xxxx Additionally activates second channel via

Camera Link connector O2 and O4.

60

Table 28: Baud rate: hexadecimal weights for each setting