Begun (see, Figure 28: piv mode flow diagram, 56). this requires – ALLIED Vision Technologies Bonito CL-400 200 fps User Manual

Page 56

Advertising
background image

Parameters and commands

Bonito Technical Manual V2.3.0

56

Sets the Exposure feature mode to Standard. (weight =

0)

Even though the Exposure feature mode is set to Standard, not to Perma-
nent Exposure mode, the exposure is always active, due to activation of
the PIV mode.

M=7

(0x7 = 0b111), sets the bit field to „- - 0 0 - 1 1 1“.

Activates Image on Demand mode (IOD) with exposure timer and frame
duration timer mode (weight =

3)

Activates PIV mode (weight =

4)

Sets the Exposure feature mode to Standard. (weight =

0)

Figure 28: PIV mode flow diagram

Advertising