ALLIED Vision Technologies Bonito CL-400 200 fps User Manual

Page 46

Advertising
background image

Parameters and commands

Bonito Technical Manual V2.3.0

46

Range

From

0 to 7, from 10 to 17, from 20 to 27, from 30 to 37

Default

0

Related

Parameters

D, E, F, J, N, and S

Three sub-fields are available to control the exposure time and frame duration
of the Bonito CL-400B/C:

Exposure timing mode

PIV mode

Exposure feature mode

All of these sub-fields are controlled by the parameter

M, each of them working

independently from the other sub-fields. The sub-fields within the parameter

M

are represented by differently sized bit groups.

To set a sub-field to a certain value, modify the associated bit group by allocat-
ing

M to the appropriate hexadecimal number.

Parameter

Value

Line Duration (

S=0)

t

L

= 3 μs

Line Duration (

S=1)

t

L

= 1.5 μs

Line Duration (

S=3)

t

L

= 1.5 μs

Frame Output Time (

D=0)

t

F

= (N + 1) * t

L

Frame Output Time (

D=1)

t

F

= 2 * (N + 1) * t

L

Minimum Frame Duration

t

FDmin

= t

F

+ t

L

Timer Resolution

t

TR

= (K + 1) / 56 MHz

Table 8: Exposure control parameters

Bit group

Sub-field description

e

Exposure timing mode

p

PIV mode

f

Exposure feature mode

Table 9: Exposure control mode: attribution of bit groups and sub-fields

7

6

5

4

3

2

1

0

-

-

f

f

-

p

e

e

rw

rw

rw

rw

rw

Table 10: Exposure control mode: order of bit groups within parameter

M

Advertising