Secondary starting address (b), Fixed pattern noise (fpn) correction (c), Chapter – ALLIED Vision Technologies Bonito CL-400 200 fps User Manual

Page 39

Advertising
background image

Parameters and commands

Bonito Technical Manual V2.3.0

39

Secondary starting address (B)

The value of parameter

B is used to create the secondary region of interest

(ROI2).

If the double ROI mode is active,

B defines the line of the image sensor that is

the first line of the second half of the output image.

Range

From

0 (topmost line) to 6BD (lowermost line)

Default

0

Related

Parameters

A, B, D, N and I

Example

A=F

start first AOI at the 16th line

B=1F

(0x1F = 31), starts second AOI at the 32nd line

D=1

enable double ROI mode

N=F

read 16 lines from each ROI, 32 lines in the output image

I=1

read every line

Fixed pattern noise (FPN) correction (C)

The Bonito camera provides an FPN correction to improve image quality. Correc-
tion data has to be recorded under low-light conditions. For best correction
quality new correction data should be acquired from time to time.

Range

0, 1, or 3 (value 3 is write-only, will be read as 1)

Default

0

Related

Parameter

M

Example

To acquire new FPN correction data follow this sequence:

Try to eliminate bright light sources, e.g. switch them off if possible. For
best correction quality, close the iris or use a lens cover.

Ensure that the camera continuously outputs images at a constant frame
rate, e.g. using the continuous mode:

>M=0[CR]

>

Note

For more information on double ROI mode and a diagram dis-
playing the ROI parameters, see chapter

Double region of

interest mode (D)

on page 40.

Each image sensor line can only be read once per exposure. Two
ROIs are only possible as long as they do not share the same
line addresses.

Advertising