Image on demand mode (iod) with exposure timer – ALLIED Vision Technologies Bonito CL-400 200 fps User Manual

Page 49

Advertising
background image

Parameters and commands

Bonito Technical Manual V2.3.0

49

The next falling edge stops the exposure and starts the output of the image syn-
chronized to the next line.

Due to the line jitter the next rising edge of the trigger should not appear earlier
than t

FDmin

+ t

L

after the previous rising edge.

Image on demand mode (IOD) with exposure timer

Bit group: e

Value: 2

The exposure time is controlled by the parameter

E.

Each rising edge of an externally applied signal starts one exposure. Use param-
eter

T to select the signal source.

A rising edge at the corresponding input starts exposure synchronized to the
line after the next.

The next rising edge must not arrive earlier than

t

FDmin

+ t

L

or

Figure 24: Exposure timing mode, M=1, flow diagram

Parameter

Value

Trigger Period

t

TP

> t

FDmin

+ t

L

Trigger High Duration

t

L

< t

TH

< t

TP

– t

L

Exposure Jitter

0 < t

j

< t

L

Exposure Time

t

Exp

= t

TH

– t

L

± t

j

Table 13: Exposure timing mode,

M=1, timing parameters