ALLIED Vision Technologies Bonito CL-400 200 fps User Manual

Page 47

Advertising
background image

Parameters and commands

Bonito Technical Manual V2.3.0

47

Since all of the sub-fields are set using the parameter

M, it is only possible to set

all of them at the same time. The value of

M is calculated as the aggregate sum

of the hexadecimal values that are set to each of the three sub-fields.

The table below shows the hexadecimal weights that can be set for each sub-
field. To work out the final value for

M, select a setting for each sub-field, then

add up the corresponding hexadecimal values.

See the following pages for detailed explanation of each sub-field.

Examples

M=0 (Default)

Sets the bit field to „- - 0 0 - 0 0 0“

Activates Continuous mode (weight =

0)

Deactivates PIV mode (weight =

0)

Activates Standard exposure feature mode (weight =

0)

M=21

(0x21 = 0b100001), sets the bit field to „- - 1 0 - 0 0 1“

Activates Image on demand mode (IOD) (weight =

1)

Deactivates PIV mode (weight =

0)

Activates Permanent exposure mode (weight =

20)

M=22

(0x22 = 0b100010), sets the bit field to „- - 1 0 - 0 1 0“

Bit values

Setting

Weight
(hexadecimal)

Exposure timing mode

--xx-x00 Continuous mode

0

--xx-x01 Image on demand mode (IOD)

1

--xx-x10 Image on demand mode (IOD)

with exposure timer

2

--xx-x11 Image on demand mode (IOD)

with exposure timer and frame duration timer

3

PIV mode

--xx-0xx PIV mode off

0

--xx-1xx PIV mode on

4

Exposure feature mode

--00-xxx Standard mode

0

--01-xxx Enhanced full well (3T) mode

10

--10-xxx Permanent exposure mode

20

--11-xxx Reserved value

30

Table 11: Exposure control mode: values for each setting

Advertising