Pneumatic connections, Accessory, . pneumatic.connections – Burkert Type 8650 User Manual

Page 45: . accessory

Advertising
background image

45

NOTE!

Pressure.supply!

When using the P shut-off basic modules, ensure that the pressure supply to the valve islands is
configured with a sufficiently large volume. (Minimum hose diameter 8/6 mm)

4.2.4.

Overview

3

5

6

7

8

9

2

1

4

Legend

1

2

3

4

5

6

7

8

9

check valve (optional)

Labeling of valve positions and installed
options

Inclined tie rods

Service ports
(assignment dependant on valve type)

Flange for valve

P shut-off (optional, only for certain versions)

X channel

R- & S channel

P channel

Fig. 16: Overview - Basic pneumatic module (Station width: 44 mm, with the options check valves and P shut-off)

4.3.

Pneumatic Connections

1

2

Possible.configuration.of.the.service.ports

Position

Valves.

Double.

valves

3/2-way

5/2-way

2x.3/2-way

6524/6526

6525/6527

6524/6526

1

not used

2

2 (valve 12)

2

2

4

4 (valve 14)

Fig. 17: Possible configuration of the service ports - basic pneumatic module

4.4.

Accessory

Basic.pneumatic.module.-.Accessory

Ident.nr.

Plug to block P-channel
(to build up several pressure levels or medium groups in a AirLINE Ex system type 8650)

655 068

Type 8650

english

Configuration and Function of the

Modules

Advertising