Ordering chart – Burkert Type 8650 User Manual

Page 55

Advertising
background image

55

7.2.3.

Ordering Chart

Description

Orifice

QNn-.
value.
air

Rated

.power

Pressure

.range

Switching.
times

Ident.no.

Opening

Closing

[l/min]

[W]

[bar]

[ms]

[ms]

C.=.NC (normally closed)

12

3

2

1

10

3/2-way valve, pilot controlled, current-free,
outlet port 2 relieved

6

700

0.3

2 ... 10

80

90

175 634
175 674

2)

0.3

-0,9 ... 8

80

90

175 673

1)

175 723

1,2)

0.3

1 ... 8

80

90

175 731

1)

D.=.NO.(normally open)

12

3

2

1

10

3/2-way valve, pilot controlled, current-free,
outlet port 2 pressurized

6

700

0.3

2 ... 8

80

90

175 725
175 726

2)

H

12

3

2

5

14

1

4

5/2-way valve, pilot controlled, current-free,
outlet port 1 with outlet port 2,
outlet port 4 vented

6

700

0.3

2 ... 8

80

90

175 727
175 728

2)

0.3

1 ... 8

80

90

175 729

1)

1)

Version with auxiliary control air

2)

Without manual override

Type 8650

english

Configuration and Function of the

Modules

Advertising