. pneumatic.valves.types.6526/6527, Station.width.16.5.mm) – Burkert Type 8650 User Manual

Page 54

Advertising
background image

54

7.2.

Pneumatic Valves Types 6526/6527
(station width 16.5 mm)

7.2.1.

Configuration and Function

The valves of Type 6526 and 6527 consist of an Ex-i pilot solenoid valve (Type 6106) and a pneumatic seat valve
as an amplifier.

The operating principle enables high pressures to be controlled with low power consumption and short switching
times.
Normally, the pilot control valves are equipped with an emergency manual override (versions without this feature
are available)

Fig. 30: Pneumatic valves type 6526 and type 6527

7.2.2.

Technical Data

Housing material

PA (polyamide)

Gasket material

NBR

Media

dry compressed air, oiled or oil-free
neutral gases (10 μm filter recommended)

Line connection

Flange for MP13

Pneumatic module

Type MP13 with G 1/8“, NPT 1/8“ or
Type MP13 with plug-and-socket connection Ø 8 mm

Manual override

yes (alternative versions without)

Rated power

0.3 W

Rated operating mode

100 % continuous operation

Electrical connection at the valve rectangular plug RM 5.08 mm

Installation

with 2 screws M3 x 30

Type 8650

english

Configuration and Function of the
Modules

Advertising