3 wiring plan – Burkert Type 8136 User Manual

Page 27

Advertising
background image

5

Insert the cable into the sensor through the cable entry

Fig. 22: Connection steps 5 and 6

6

Insert the wire ends into the terminals according to the wiring plan

Information:
Solid cores as well as flexible cores with cable end sleeves are
inserted directly into the terminal openings. In case of flexible cores
without end sleeves, press the terminal head with a small screwdriver;
the terminal opening is freed. When the screwdriver is released, the
terminal closes again.

7

Check the hold of the wires in the terminals by lightly pulling on
them

8

Connect the screen to the internal ground terminal, connect the
outer ground terminal to potential equalisation

9

Tighten the compression nut of the cable entry. The seal ring must
completely encircle the cable

10 Screw the housing cover back on

The electrical connection is finished.

Information:
The terminal block is pluggable and can be removed from the
electronics. To do this, lift the terminal block with a small screwdriver
and pull it out. When inserting the terminal block again, you should
hear it snap in.

5

.3 Wiring plan

The following illustration applies to the non-Ex as well as to the Ex-ia
version.

LEVEL TRANSMITTER 8136 • 4 … 20 mA/HART - two-wire

27

5 Connecting to power supply

41783

-EN

-

120316