Burkert Type 8136 User Manual

Page 63

Advertising
background image

Additional deviation through strong, high
frequency electromagnetic fields acc. to EN
61326

<±50

mm

Specifications apply also to the current output

Temperature drift - Current output

±0

.03 %/10 K relating to the 16 mA span max.

±0

.3 %

Deviation on the current output by analogue/
digital conversion

<±15 µA

Deviation on the current output by strong,
high frequency electromagnetic fields within
EN 61326

<±150 µA

Characteristics and performance data

Frequency

K-band (26 GHz technology)

Measuring cycle time

-

Standard electronics approx.

450 ms

-

Electronics with increased sensitivity
approx.

700 ms

Step response time

2)

≤ 3

s

Tracking speed of the measuring window
max.

1 m/min

Beam angle

3)

-

Encapsulated antenna system

22°

-

Plastic horn antenna

10°

Emitted HF power (depending on the parameter adjustment)

4)

-

Average spectral transmission power
density

-14 dBm/MHz EIRP

-

Max. spectral transmission power den-
sity

+43

dBm/50 MHz EIRP

-

Max. power density in a distance of 1 m

< 1 µW/

cm²

Ambient conditions

Ambient, storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

For the process conditions, please also note the specifications on the type label. The lower value
always applies.

2)

Time span after a sudden measuring distance change by max. 0.5 m in
liquid applications, max 2 m with bulk solids applications, until the output
signal has taken for the first time 90 % of the final value (IEC 61298-2).

3)

Outside the specified beam angle, the energy of the radar signal has a level
which is reduced by 50 % (-3 dB)

4)

EIRP: Equivalent Isotropic Radiated Power

LEVEL TRANSMITTER 8136 • 4 … 20 mA/HART - two-wire

63

11 Supplement

41783

-EN

-

120316