Burkert Type 8136 User Manual
Page 62
0,5 m (1.6 ft)
10 mm (0.394 in)
- 10 mm (- 0.394 in)
2 mm (0.079 in)
- 2 mm (- 0.079 in)
0
1 2
3
Fig. 42: Deviation under reference conditions - encapsulated antenna system
1
Reference plane
2
Antenna edge
3
Recommended measuring range
0,5 m (1.6 ft)
10 mm (0.394 in)
- 10 mm (- 0.394 in)
2 mm (0.079 in)
- 2 mm (- 0.079 in)
0
1
2
3
Fig. 43: Deviation under reference conditions - plastic horn antenna
1
Reference plane
2
Antenna edge
3
Recommended measuring range
Reproducibility
≤ ±1
mm
Deviation with bulk solids
The values depend to a great extent on the
application. Binding specifications are thus not
possible.
Variables influencing measurement accuracy
Specifications apply to the HART signal and the current output
Temperature drift - Digital output
±3
mm/10 K relating to the max. measuring range
or max. 10 mm
62
LEVEL TRANSMITTER 8136 • 4 … 20 mA/HART - two-wire
11 Supplement
41783
-EN
-120316