Burkert Type 8136 User Manual

Page 60

Advertising
background image

-

Aluminium/Stainless steel housing

50 Nm (36.88 lbf ft)

Input variable

Measured variable

The measured quantity is the distance between
process fitting of the sensor and product surface.
The reference plane is the seal surface on the
hexagon or the lower side of the flange.

3

4

2

1

Fig. 41: Data of the input variable

1

Reference plane

2

Measured variable, max. measuring range

3

Antenna length

4

Useful measuring range

Standard electronics

Max. measuring range

35 m (114.8 ft)

Recommended measuring range

-

Encapsulated antenna system

up to 10 m (32.81 ft)

-

Plastic horn antenna

up to 20 m (65.62 ft)

Electronics with increased sensitivity

Max. measuring range

35 m (114.8 ft)

Recommended measuring range

-

Encapsulated antenna system

up to 10 m (32.81 ft)

-

Plastic horn antenna

up to 20 m (65.62 ft)

Output variable

Output signal

4 … 20 mA/HART

Fulfilled HART specification

7.0