Operation 79, Figure 4-6 parameter table of the positioner – Cashco Siemens PS2 I/P User Manual

Page 79

Advertising
background image

Operation

79

SIPART PS2 Manual

A5E00074631-01

(example)

3.YWAY

2)

1)

4.INITA

5.INITM

6.SCUR

10.TSUP

11.TSDO

12.SFCT

13.SL0

14.SL1
usw. bis
32.SL19
33.SL20

9.SPRE

8.SPRA

7.SDIR

3)

2.YAGL

1.YFCT

34.DEBA

35.YA

36.YE

39.YCLS

40.YCDO

41.YCUP

37.YNRM

38.YDIR

5)

5)

43.BIN2

44.AFCT

45.A1

46.A2

42.BIN1

4)

4)

55.PRST

48. TIM

47. FCT

49. LIM

50. STRK

51. DCHG

52. ZERO

53. OPEN

54. DEBA

OFF

OFF

OFF

0,0 bis 100,0

0,0 bis 100,0

on

uP

doWn

StoP

-on
-uP

-doWn

-StoP

on

bLoc1
bLoc2

uP

doWn

StoP

-on

-uP

-doWn

-StoP

no

Strt

oCAY

Auto

0,0 bis 100,0

OFF

1 bis 1.00E9

OFF

1 bis 1.00E9

OFF

0,0 bis 100,0

OFF

0,0 bis 100,0

OFF

0,0 bis 10,0

Auto

0 bis 100

noini | no / ###.# | Strt

0 MA
4 MA

riSE

FALL

riSE

FALL

Auto

0 bis 400

0 bis 400

Lin

1 - 33

FrEE

n1 - 33

1 - 50
n1 - 50

1- 25

n1 - 25

0,0 bis 100,0

25 | 30 | 35

40 | 50 | 60 | 70 | 90 | 110 | 130

5 | 10 | 15 | 20

(kurzer Hebel 33°)

(kurzer Hebel 90°)

(langer Hebel 90°)

Auto

0,1 bis 10,0

0,0 bis 100,0

0,0 bis 100,0

0,0 bis 100,0

0,0 bis 100,0

0,0 bis 100,0

0,0 bis 100,0

MPOS
FLOW

no
uP

do

uP do

OFF

OFF

noini | no / ###.# | Strt

%

%

%

%

%

%

%

s

%

%

%

%

%

s

s

%

%

mm

33°

WAY

0.0

5.0

usw. bis

95.0

100.0

Lin

0

0

riSE

riSE

OFF

no

no

4 MA

no

MPOS

100,0

99,5

0,0

0,0

100

0,5

Auto

90,0

10,0

OFF

OFF

OFF

Auto

Auto

OFF

OFF

OFF

OFF

OFF

OFF

OFF

90°
33°

Parameter name

Display

Function

Parameter values

Unit

Factory setting

Customer setting

Rated angle of rotation of feedback

Type of actuator

turn (part-turn actuator)

WAY (linear actuator)

LWAY (linear actuator

without sine correction)

ncSt (part-turn actuator with NCS)

-ncSt (ditto, inv. direction of action

Set transmission ratio selector (7) appropriately
(see view of device)

Degrees

Stroke range (optional setting)

When used, the value must correspond with
the set of the leverage ratio on the actuator

Driver pin must be set to the value of the actuator
travel or, if this value is not scaled, to the next
larger scale value.

Initialization (automatically)

Initialization (manually)

Setpoint ramp up

Setpoint direction

0 to 20 mA
4 to 20 mA

rising

falling

Current range of setpoint

Setpoint for start of split range

Setpoint for end of split range

Setpoint ramp down

Setpoint function

Linear

Equal-percentage 1:25, 1:33, 1:50

Inverse equal-percentage

Freely adjustable

1:25, 1:33, 1:50

Setpoint turning point at 0%

5%

to

95%

100%

Dead zone of controller

Start of manipulated variable limiting

End of manipulated variable limiting

Standardization of
manipulated variable

To mech. travel

To flow

None

Only message

Block configuring

Block configuring and manual

Drive valve to position up

Drive valve to position down

Block movement

Function of BI 1

Tight closing with
manipulated variable

Value for tight closing, bottom

Value for tight closing, top

Direction of manipulated
variable for display

Without

Top only

Bottom only

Top and bottom

Rising

Falling

NO

c

o

nt

a

ct

NO c

o

nt

a

ct

None

Only message

Drive valve to position up

Drive valve to position down

Block movement

Alarm function

Without
A1=min. A2=max
A1=min. A2=min
A1=max. A2=max

Response threshold of alarm 1

Response threshold of alarm 2

no

rm

a

l

no

rm

a

l

Function of BI 2

on fault

Fault + not automatic

Fault + not automatic + BI

("+" means logical OR operation)

Monitoring time for fault message
“control deviation”

Preset (factory setting)
"no" nothing activated
"Strt" start of factory setting after pressing key for 5 s
"oCAY" display following successful factory setting
CAUTION: preset results in "NO INIT"

Response threshold for fault message
“control deviation”

Limit for stroke integral

Function of alarm output

in

ve

rt

e

d

in

ve

rt

e

d

N

C

co

n

ta

c

t

N

C

co

n

ta

ct

Limit for direction change

Limit for end stop monitoring, bottom

Limit for end stop monitoring, top

Limit for dead zone monitoring

If "turn" is selected, you cannot set 33°
Parameter does not appear if 1.YFCT=turn has been selected
Turning points only appear wih selection 12.SFCT = FrEE
Alternatively "no" if initialization has not yet been carried out

NC contact means:
NO contact means:
Normal means: High level without fault
Inverted means: Low level without fault

1)
2)
3)
4)

5)

6)

action with opened switch or Low level
action with closed switch or High level

1)
2)
3)

Figure 4-6

Parameter table of the positioner