3. Program the PROM device with the appropriate file, according to the instructions for the

PROM programmer being used.

Note:

The load address for the S record is 0xFFF00000.

4. Confirm that the checksum of the programmed device matches that detailed in the Eclipse HX

Release Notes.

5. Remove the existing PROM device from the configuration card.

6. Insert the newly programmed PROM device taking care to ensure the correct polarity of the

device.

Observe all electrical shock hazard warning and precautions for handling
electrostatic sensitive devices


9.6 Upgrading the E-QUE card (MK2) boot ROM

Only upgrade the E-QUE (MK2) boot ROM after the main E-QUE application code has been
upgraded.

Note:

The procedure below is for E-QUE (MK2) cards only. To upgrade the PROM of an E-QUE card
(MK2), see 9.5 Upgrading the E-QUE card (MK1) boot
ROM.

To upgrade the E-QUE (MK2) boot PROM:

1. Ensure that you have the following equipment:

Required equipment

Description / comments

Tera Term software

Tera Term must be configured and operational. You can
find the Tera Term application on both of the Eclipse HX
7.5 DVDs:

Software DVD > 3rd_Party_Software > Teraterm

Hardware DVD > 3rd_Party_Software > Teraterm

TFTP Server software

-

MVX Serial cable (CAB-MVX-
48Z)

See Figure 55: MVX-A16 serial cable (CAB-MVX-48Z)

Ethernet crossover cable

-

Small reset tool

For example, a bent paper clip

Table 29: Required equipment

101

Eclipse HX Upgrade Guide

Advertising
This manual is related to the following products: