3 manually upgrading e-station application code, Manually upgrading e-station application code – Clear-Com HX System Frames User Manual

Page 137

Advertising
background image

11. When the download process is complete, Tera-Term will display the message on the PC

Download Success!

Exit Tera Term and reboot the I-Series panel to leave maintenance / update mode. Press 9
on the PC keyboard and then Enter.

The I-Series panel begins its reset process.

Note:

When the reset process is underway, the display modules briefly display the updated
firmware version. If the I-Series is re-connected to an Eclipse HX matrix with a valid
configuration press keypad button 9 to access the updated firmware/rack code version.

Figure 95: Example version display

Note:

If the manual upgrade fails repeat the above procedure. It can be necessary to attempt the manual
process up to 3-5 times before the application is installed.

13.2.3

Manually upgrading E-Station application code

The procedure for upgrading the E-station application code is very similar to the procedure for
upgrading the I-Series panel application code (see 13.2.2 Manually upgrading I-Series panel
application code
).

To manually upgrade the E-Station:

1. Connect the converter cable to the expansion in RJ-45 port (J1) on the E-station

undergoing the upgrade.

If the cable has separate I-Series and E-station CAT5 cables, the E-station CAT5 cable
lead is used for the connection to J1 on the E-station. Connect the other end of the cable to
the serial port of the PC running the Tera-Term software.


Note:

The E-Station must not be powered while the cable is connected.

Figure 96: E-Station manual upgrade

130

Eclipse HX Upgrade Guide

Advertising