8. Click Next and confirm that the details displayed are correct.

9. Click Next and confirm that the download commences.

10. When the download has completed, click Finish to close the update firmware wizard.

Note:

The MVX-A16 card status light

flashes green

while the upgrade is in process (LED on to off

ratio: 1:4 at 0.5Hz). When the upgrade is complete, the status light is lit

green

at a steady

heartbeat (LED on to off ratio: 1:1 at 1Hz).

11. Ensure that the MVX-A16 cards reset once the download is complete. Reset should take

approximately 1 minute.

7.1.2 Upgrading the MVX-A16 card boot and application code using

the Renesas FDT

Remove power from the devices first, to avoid working with the system while it
is live. Observe all electrical shock hazard warning and precautions for
handling electrostatic sensitive devices

You can use the Renesas FDT to upgrade:

• The MVX boot code file separately (*.mot).

• The MVX boot code and MVX application code simultaneously, using the combined MVX

boot and application code file (*.mot).

Tip:

For more information about installing and configuring the Renesas FDT, see

Appendix D: Hitachi Renesas Flash Development Tool.

To upgrade the MVX code (MVX boot code or combined MVX boot and application code) for the
MVX-A16 card:

1. Ensure that you have the following equipment:

Required equipment

Description / comments

PC with a serial port
connection or USB-to-serial
port adaptor

If you are using a USB-to-serial port adaptor, download
the latest drivers.

Renesas Flash Development
Toolkit 3.4 Basic (FDT)

The Renesas FDT must be installed and configured. You
can find the Renesas FDT application on both of the
Eclipse HX v7.5 DVDs:

Software DVD > 3rd_Party_Software > RenesasFDT

Hardware DVD > 3rd_Party_Software > RenesasFDT