Clear-Com HX System Frames User Manual

Page 43

Advertising
background image

7. Use the EHX firmware report to verify that the correct version of the U1 CPLD is now loaded.

8. If the upgrade has been completed disable the CPLD upgrade functionality by setting the DIP

switches to the following settings.

5.9 Upgrading the CPU card U53 CPLD code with Xilinx

tools

Use the following procedure to upgrade the U53 CPLD code for the CPU card.

To upgrade the CPU U53 CPLD code with Xilinx tools:

1. Check that you have the latest version of Xilinx tools installed.

Tip:

Upgrading the CPU card(s) CPLD code using Xilinx tools requires specialized

equipment. For more information about installing Xilinx programming tools, see
Appendix I:Xilinx tools.

2. Connect the USB connector of the download cable (Platform cable USB DLC9G) to the USB

port of the PC.

3. Connect the 14way IDC header to CON11.

4. Power up the CPU card and start the iMPACT programming tool.

5. In Load Project, select Cancel.

6. Hold the CPU card in reset by inserting a suitable tool into the Reset pin at the top of the

card. You must press and hold the reset pin during the whole upgrade process.

7. In Flows, double click Boundary Scan. Right click the main window and select

Initialise Chain / Ctrl+ I:

36

Eclipse HX Upgrade Guide