6.5.1 Upgrading the Eclipse HX-PiCo MVX application code

with EHX

Important note:

To upgrade the Eclipse HX-PiCo MVX application code with EHX, your system must already be
running a version of Eclipse HX.

Recommendation

Clear-Com recommends that you monitor the MVX application code upgrade using the Event Log in
EHX. The upgrade process is complete when the MVXs on the Eclipse HX-PiCo briefly disappear and
then reappear in the log. To check that the upgrade has been successful, run a firmware report.

If the upgrade is unsuccessful, use the Renesas FDT to upgrade the MVX code
(see 6.5.2 Upgrading the Eclipse HX-PiCo MVX boot and/or application code using the Renesas
FDT
).

To upgrade the Eclipse HX-PiCo MVX application code using EHX:

1. Ensure that you have the following equipment:

Required equipment

Description / comments

PC with an Ethernet connector

-

Serial cable or Ethernet cable for
the PC to matrix connection

-

EHX installation

EHX must be configured and operational.

An EHX configuration file (*.hxn
or *.ccn format)

The configuration file must have an appropriate IP
address set.

The appropriate *.fwc format file
for the Eclipse HX-PiCo MVX
cards / sections

You can find the Eclipse HX-PiCo MVX application
code (*.fwc) file on the software DVD:

Software DVD > Eclipse HX-PiCo > xxxxxxZ-MVX
Application

Table 16: Required equipment

2. Start EHX on the PC.

3. Connect the PC to the matrix using either Ethernet or a serial communications port.

4. Open the EHX configuration map within EHX. Select System > Layout.

5. Right click the matrix and then select Firmware> Update Firmware.