A760 User Guide: Programming Supplement
Chapter 4: Programming commands

102

Revision F January 2010

Set GS1 DataBar (RSS) parameters

Setting of parameters for RSS barcode

ASCII

GS q a b c d e fL fH

Hexadecimal 1D 71 a b c d e fL fH
Decimal

29 113 a b c d e fL fH

a

byte

pixels per minimum unit, default 3, minimum 2, maximum 6 (value a applies

to parameters b, c, d)

b

byte

X undercut, default 0, can be set 0 to a-1

c

byte

Y undercut, default 0, can be set 0 to a-1

d

byte

separator height, default a, can be set a to a*2

e

byte

segment width, used only by GS1 Expanded and Expanded Stacked,

default 22, must be even number

2 to 22

f

word

line height, used only by UCC128, default 25, can be set 1 to 500

Note: For GS1 DataBar commands, consult ISO/IEC 24721. For further information, visit www.gs1.org.

Print GS1 DataBar (RSS), data length specified

ASCII

GS k m nL nH d1... dn

Hexadecimal

1D 6B m nL nH d1... dn

Decimal

29 107 m nL nH d1... dn

m

Type

61

GS1

62

GS1 Truncated

63

GS1 Stacked

64

GS1 Stacked Omnidirectional

65

GS1 Limited

66

GS1 Expanded and Expanded Stacked

67

UPC-A

68

UPC-E

69

EAN-13

6A

EAN-8

6B

UCC/EAN-128 with CC-A or CC-B

6C

UCC/EAN-128 with CC-C

Note: Data length specified 1 to 2436 via integer nH : nL.