2.2 Terminal

Descriptions

MAIN DESCRIPTION

1

Phone Line Connection – 800 ft. maximum with 24 AWG wire; 1600 ft. maximum with 22 AWG wire.

2

Phone Line Connection – 800 ft. maximum with 24 AWG wire; 1600 ft. maximum with 22 AWG wire.

3 Earth

Ground

Only.

4

Switch Input. A closure between terminals 4 and 6 will cause the designated relay(s) to activate for the
programmed strike time or dial a phone number – see 3.2.6. The Postal Switch is connected here.

5 Microphone

Input.

6

Common for switch input, microphone, speaker, AZ & CALL buttons and battery negative.

7 Speaker

Output.

8 (not

used).

9

5 VDC Power for LED lighting.

10 (not

used).

11

Z Button Input.

12

A Button Input.

13

Relay 2 Common – 30 Volt, 3 Amp maximum.

14

Relay 2 Contact – 30 Volt, 3 Amp maximum.

15

Relay 1 Common – 30 Volt, 3 Amp maximum.

16

Relay 1 Normally Closed – 30 Volt, 3 Amp maximum.

17

Relay 1 Normally Open – 30 Volt, 3 Amp maximum.

18

Back-up Battery POSITIVE (connect negative to terminal 6).

19

16 VAC Input Power – 20 VA minimum for 1833, 1834 and 1835; 40 VA minimum for 1837.
100 ft. maximum with 18 AWG wire; 200 ft. maximum with 16 AWG wire.

20

16 VAC Input Power – 20 VA minimum for 1833, 1834 and 1835, 40 VA minimum for 1837.
100 ft. maximum with 18 AWG wire; 200 ft. maximum with 16 AWG wire.

AUXILIARY DESCRIPTION

1

16 VAC Input Power – 20 VA.

2

16 VAC Input Power – 20 VA.

3 Back-up

Battery

POSITIVE.

4 Back-up

Battery

NEGATIVE.

5

16 VAC Output.

6

16 VAC Output.

7

DATA 0 – Card Reader 2.

8

DATA 1 – Card Reader 2.

9

COMMON – Card Reader 2.

10

+12 VDC Power – Card Reader 2.

11

DATA 0 – Card Reader 1.

12

DATA 1 – Card Reader 1.

13

COMMON – Card Reader 1.

14

+12 VDC Power – Card Reader 1.

ELEVATOR DESCRIPTION

1

DATA 1 – connect to Elevator Control Board (2348-010) Terminal 20.

2

DATA 0 – connect to Elevator Control Board (2348-010) Terminal 21.

3

COMMON – connect to Elevator Control Board (2348-010) Terminal 22.


NOTE: Auxiliary and Elevator Control terminals are not available on the 1834 model.