3.2.7

Switch Input Function

The following programming sequence sets the switch input (terminals 4 and 6) to either activate a
relay(s) or call the phone number programmed in directory code 0, 00, 000 or 0000. Refer to section
3.3.4 to determine which relay(s) will activate when the switch input is activated. This feature is
available on Rev K boards or higher.

Factory setting = 0 (switch input activates relay)

1. Press * 1 8 and then enter the four digit master code _ _ _ _ (beep). The display on the

1835 and 1837 systems will read: KEY IN DIAL? 0=N 1=Y

2. Enter 1 for yes (the switch input will dial a phone number) or 0 for no (the switch input will

activate the relay) then press * (beep).

3. Press 0 # together to end this programming sequence (beeeeeep).

3.2.8

Elevator Control Function

This new elevator feature authorizes floor access to the Floor Level identified in the Resident Screen
in the software program AND to the floor(s) level identified in the Security Level screen. If this feature
is turned off, access will be granted only the floor identified in the user’s security level. This feature is
available on Rev K boards or higher.

Factory setting = 1 (new elevator function is turned on)

1. Press * 7 5 and then enter the four digit master code _ _ _ _ (beep). The display on the

1835 and 1837 systems will read: NEW EL FUNC? 0=N 1=Y

2. Enter 1 for yes (access is authorized to both the floor identified in the resident screen and

to the floor(s) identified in the user’s security level) or 0 for no (access is authorized only
to the floor(s) identified in the security level screen) then press * (beep).

3. Press 0 # together to end this programming sequence (beeeeeep).

STOP!!

If the telephone entry system is to be programmed from a PC, no other programming is required at
the system itself. Refer to the Remote Account Manager for Windows Software help screens for
additional programming information. Continue with the remaining sections in this chapter if the
telephone entry system will be programmed by any other method. If the factory setting matches your
need, there is no reason to reprogram that section.

Remember that relay hold open time zones, security levels, and elevator control functions can only be
programmed from the Remote Account Manager Software. If any of these features are being used,
do not proceed with any other programming steps in this manual.