3 controller & expansion boards 1-16, Page – Controlled Products Systems Group 1834-080 User Manual

Page 26

Advertising
background image

2.3.3

Controller & Expansion Boards 1-16

Mai

n

T

e

rmi

n

al

18

33,

1

83

5, 1

8

37

, 18

3

8

CON

T

ROLLE

R

N

O

TE

S:

Co

nt

ro

lle

r

ma

in

te

rm

in

a

ls

15-

1

6

-1

7 =

SY

S

T

E

M

R

E

LA

Y

1.

Co

nt

ro

lle

r

ma

in

te

rm

in

a

ls

13-

1

4

= SY

STEM

RE

LAY 2.

A

u

xili

a

ry Ter

m

in

als

14
13
12
11

10

9
8
7

6
5

4
3

2
1

+ 12 VDC

COMMON

DATA 1
DATA 0

Elevator

Control

RS 232
Connection

1
2
3
4
5
6

1
2
3

1 2 3

17

16

15

14

13

20

19

4

6

18

30 Series Controller to 2351-010 Expansion Boards 1-16
Detail Wiring

C.O.
PHN

16 VAC

PWR

INPUT

BLU

BR

N

To

Boards

3-8

DOORKING, INC., INGLEWOOD, CA 90301

Date:

Dwg. No.

Detail Wiring - 30 Series Controller to 2351-010
Expansion Boards 1-16

Rev.

Title:

10/11

D

M1835-065-4

To Main
Door / Gate

Central Office phone line - touch tone, loop start.

2

A switch closure across terminals 4 & 6 will activate relay 1
for its programmed strike time.

Battery Backup - separate batteries required for phone
system and weigand terminals.

3

16 Volt, 20 VA UL Listed Transformer.

4

1

2

4

4

6 conductor, stranded with overall shield, 18, 20, 22 or 24 gauge is
sufficient for these connections.

4 conductor, stranded with overall shield, 18, 20, 22 or 24 gauge is
sufficient for these connections.

Communication cable to additional boards is connected in parallel. Allows “teeing” of
communication cable for optimal cable routing.

For 1837, use 16 Volt, 40 VA UL Listed Transformer.

Power for door strikes or magnetic locks is not provided by the system. It must be
provided by an external power supply.

Aux power transformer must be connected. Otherwise, RS232, elevator control and
weigand inputs will not function.

No connection at controller.

12

9

10

11

5

6

7

8

See Dwg No. M1835-065-5 for
detail.

5

11

9

8

12

16 VAC
OUTPUT

1

+

3

13

EARTH Ground.

13

Relay 0

NO

NC

CO

M

+ 12 VDC

COMMON

DATA 1
DATA 0

BL

U

BR

N

6

7

16 VAC

PWR

INPUT

+

3

10

P2

P1

6
7
8
9

10

17

5
6

7
8
9

12
13
14

2351-010

LOCK

PWR

DOOR

LOCK

P2

P1

6
7
8
9

10

17

5
6

7
8
9

12
13
14

2351-010

LOCK

PWR

DOOR

LOCK

P2

P1

6
7
8
9

10

17

5
6

7
8
9

12
13
14

2351-010

LOCK

PWR

DOOR

LOCK

P2

P1

6
7
8
9

10

17

5
6

7
8
9

12
13
14

2351-010

LOCK

PWR

DOOR

LOCK

RED
BLK
WHT
GRN
BRN
BLU

13

4

16 VAC

PWR

INPUT

13

4

16 VAC

PWR

INPUT

13

4

16 VAC

PWR

INPUT

13

4

16 VAC

PWR

INPUT

RED
BLK
WHT
GRN
BRN
BLU

RED
BLK
WHT
GRN
BRN
BLU

RED
BLK
WHT
GRN
BRN
BLU

RED

BLK

WHT

GRN

BRN

BLU

RED

BLK

WHT

GRN

BRN

BLU

10

10

10

7

7

7

6

To

Boards

9-16

6

6

RED
BLK
WHT
GRN
BRN
BLU

RED
BLK
WHT
GRN
BRN
BLU

11

6

6

Page

26

1835-065-R-10-11

Advertising
This manual is related to the following products: