3.6

Programming Device Codes (1833, 1835, 1837 Only)

Device codes must be five (5) digits in length and are typically card and transmitter codes. Each
device code that you enter is assigned to the directory code that you select. Up to 25 device
numbers can be entered under a single directory code, up to a maximum of 8,000 for the system.
You cannot duplicate device codes.

3.6.1

Programming Device Codes

This program sequence enters device (card, transmitter, digital) codes into the system memory.

1.

Press *70 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Enter the directory code that the device code is to be assigned to (1, 2, 3 or 4 digits
depending on what was programmed in 3.5.1) then press * (beep).

3.

Enter the five-digit device code _ _ _ _ _ then press * (beep).

4.

Repeat steps 2 and 3 to enter additional device codes.

5.

Press 0# TOGETHER to end this programming step (beeeeeep).

3.6.2

Deleting Device Codes

This program sequence deletes individual device codes.

1.

Press *71 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Enter the directory code (1, 2, 3 or 4 digits depending on what was programmed in
3.5.1) then press * (beep).

3.

Enter the five-digit device code _ _ _ _ _ then press * (beep).

4.

Repeat steps 2 and 3 to delete additional device codes.

5.

Press 0# TOGETHER to end this programming step (beeeeeep).

3.6.3

Enabling Facility Codes

This program sequence allows you to use (enable) or not use (disable) facility codes.

1.

Press *72 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Enter 0 to disable facility codes or enter 1 to enable facility codes then press * (beep).

3.

Press 0# TOGETHER to end this programming step (beeeeeep).

3.6.4

Programming Facility Codes

This program sequence enters device facility codes into the system memory. Up to 10 facility codes
(reference numbers 0 through 9) may be programmed. Valid facility codes are 000 – 255.

1.

Press *73 and enter the four-digit MASTER CODE _ _ _ _ (beep).

2.

Enter the first facility code reference number _ (0 – 9) then press * (beep).

3.

Enter the three-digit facility code _ _ _ then press * (beep).

4.

Repeat steps 2 and 3 to enter additional facility codes.

5.

Press 0# TOGETHER to end this programming step (beeeeeep).