Pressure display, Pump controls buttons – SKC DataTrac for the Leland Legacy User Manual

Page 16

Advertising
background image

13

SKC Real Time Monitor

Figure 12. Pressure Display

Figure 13. Pump

Controls Buttons

Figure 11A. Reset Volume,

Temp, Run Time, and

Pressure Button

Pressure Display

The Pressure Display (Figure 12) shows the atmospheric pressure of the air entering
the connected pump.

Cell

Readout

Min ........................................................minimum atmospheric pressure during the

program

run

Max........................................................maximum atmospheric pressure during the

program

run

TWA ......................................................time-weighted average of all atmospheric

pressure

Ambient ...............................................current atmospheric pressure

The Min, Max, and TWA are calculated from
the atmospheric pressure measured during the
total run time of the pump. Unless reset, the
pressure data will remain in memory and will
be included in future Min, Max, and TWA
calculations. Reset by clicking on the Reset
Volume, Temp, Run Time, and Pressure butt on
in the Pump Controls section of the Real Time
Monitor (Figure 11A).

Pump Controls Buttons

The Pump Controls butt ons (Figure 13) directly control the
connected pump.

Control Function
Run
...............................................places the pump in RUN
Hold ..............................................places the pump in HOLD
Set Flow .......................................opens the Monitor Set Flow

window (similar to Figure 25)

Reset Volume, Temp,
Run Time, and Pressure
.....clears the accumulated data: volume, temperature

(Min, Max, and TWA), time, and pressure (Min, Max,
and TWA)